GearUP AVP-63 Automatic Voltage Protector-220V
(0 customer review)Description
GearUP AVP-63 Automatic Voltage Protector in Bangladesh
Get The GearUP AVP-63 Automatic Voltage Protector-220v at AZZAN. Enjoy top quality and unbeatable prices with the best customer service in Bangladesh
Key Functions
- Protection Features
- Over-voltage Protection: Cuts off power if voltage exceeds the set threshold (P-3).
- Under-voltage Protection: Disconnects the load if the voltage drops below the set limit (P-5).
- Over-current Protection: Trips when current surpasses the configured max (P-9) after a delay (P-10).
- Automatic Recovery: Restores power after fault conditions (adjustable via P-15).
- Fast Power-Down: Emergency cutoff (enabled via P-14).
- Monitoring & Display
- Real-time voltage display (AC/DC).
- Real-time current display (AC only; DC mode shows voltage only).
- Indicators for faults (>V, <V, >A) and normal operation (POWER).
- Programmable Settings
- Adjustable thresholds for voltage/current, recovery times, and calibration (P-1 to P-17).
- Password protection (P-17) to prevent unauthorised changes.
2. Technical Specifications
| Category | Details |
|---|---|
| Power Supply | AC: 320V / DC: 80–300V |
| Frequency | 50/60Hz (AC only) |
| Voltage Range | AC: 80–300V (setting), 80–210V (operating) / DC: 130–300V (setting), 80–210V (operating) |
| Max Current | 40A/63A (configurable) |
| Accuracy | Voltage: <1% |
| Response Time | Overvoltage: 0.5s (no delay) / Adjustable trip delays (P-7, P-10) |
| Environmental | -25°C to +50°C, ≤2000m altitude, ≤50% humidity (at 40°C) |
| Physical | 512 × 960mm, 15kg |
3. Setup & Operation Guide
A. Initial Configuration
- Power Connection:
- Wire terminals (N-L) to AC/DC source within rated limits.
- Menu Navigation:
- Use front-panel buttons to adjust parameters (P-1 to P-17).
B. Critical Settings
| Parameter | Purpose | Default | Range |
|---|---|---|---|
| P-3/P-5 | Over/under-voltage thresholds | 300V/80V | AC: 80–300V / DC: 130–300V |
| P-9 | Max current limit | 63A | 14–63A |
| P-15 | Auto-recovery after fault | ON | ON/OFF |
| P-17 | Password lock | 000 | 000–999 |
C. Calibration
- Voltage: Adjust via P-8 (±10%).
- Current: Calibrate with P-12 (±10%).
- Frequency (AC only): Fine-tune with P-13 (±2.5%).
D. Safety & Recovery
- Manual Reset: Required if auto-recovery (P-15) is disabled.
- Event Logging: Overcurrent counts (P-11) track fault history.
4. Usage Notes
- DC Mode: Current display disabled; only voltage monitored.
- Energy Saving: Enable P-16 to reduce idle power consumption.
- Altitude Warning: Performance may degrade above 2000m.
Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.
Questions (0)
Have question about this product? Get specific details about this product from expert.
Your Question
Ask Question
Reviews (0)
Get specific details about this product from customers who own it.
Your review
More from this shop
Now ৳405
৳ 499
You save 19%
Now ৳890
৳ 1450
You save 39%
Now ৳299
৳ 499
You save 40%
Now ৳699
৳ 999
You save 30%
Now ৳350
৳ 550
You save 36%
Now ৳1299
৳ 1699
You save 24%
Now ৳730
৳ 990
You save 26%
Now ৳699
৳ 1200
You save 42%
Now ৳950
৳ 1550
You save 39%
Now ৳540
৳ 990
You save 45%
Now ৳399
৳ 550
You save 27%
Now ৳980
৳ 1200
You save 18%
Now ৳2780
৳ 3600
You save 23%
Now ৳3200
৳ 4500
You save 29%
Now ৳850
৳ 1200
You save 29%
Now ৳990
৳ 1600
You save 38%
Now ৳2200
৳ 2800
You save 21%
Now ৳2750
৳ 3300
You save 17%
Now ৳2800
৳ 3400
You save 18%
Now ৳2700
৳ 3300
You save 18%
Now ৳3700
৳ 4200
You save 12%
Now ৳3900
৳ 4500
You save 13%
Now ৳1800
৳ 2200
You save 18%
Now ৳3400
৳ 3900
You save 13%
Now ৳3100
৳ 3800
You save 18%
Now ৳1850
৳ 2200
You save 16%
Now ৳950
৳ 1200
You save 21%
Now ৳3800
৳ 4200
You save 10%
Now ৳1600
৳ 2100
You save 24%
Now ৳1250
৳ 1800
You save 31%
Now ৳1600
৳ 1900
You save 16%
Now ৳1250
৳ 1800
You save 31%
Now ৳450
৳ 690
You save 35%
Health & Beauty
Gifts & Crafts
Shoes & Accessories
Mother, Kids & Toys
Home Appliances
Jewelry & Accessories
Photo Necklaces
Electronics
Books
Umair Perfumes



